About the Project

  • Project Title Scalar - Wearhouse / Logistics Service
  • Category Logistics Service
  • Location Pune
  • Post Date 2024-10-10

Project Information

thaibet55.com

1. Standards And Building Codes National Building Code(NBC) Of Practise Carpet Area (Main Building) 217 412 Sq. Ft. Dimension Of Building 267.5 X 75.5 (Mtr) With Mezzanine Mezzanine Floor Area 12102 Sq. Ft. Bay Spacing Internal 11.60 X 24.80 Meters Clear Height Of Building Eve Height Is 12.0 Mts With 1: 20 Slope


PEB Details

2.PEB Structure Tata Blue Scope Steel Ltd
Main Frame Main Frame & All Other Primary Members Are Designed As Per The AIS-1989 9th Edition
Wind Loads As Per The IS 875 With Cpi:=/- 0.5 Terrian Category-2
Sesimic Loads As Per The IS 1893-2002-Zone -III
Purlin/Girt Pre- Galvanized-120GSM
Bracing Upto 3.5 Mts Portal Bracing & X-Rod Bracing Full Height
Roof Sheeting Standard Seam Roofing System (Screwers)
Wall Sheeting 0.5mm TCT Colour Coated Galvalume 550Mpa
Insulation Of Roofing 4mm Double Side Aluminium Wrap -Aerolum Bubble Insulation
Sky Light Poly Carbonate Sheet Single Skin Clear Transulent FRP Panles 5% Of Roof Area As Per The NBC Standards Canopy Having 8 Mts Width Of Cantilever Canopy For Docking
Cage Ladders 2 Nos Of Cage Ladders As Per The Standard Requirement.


Safety System

3. Dock Levelrs 6 Nos Of Dock Levers (Harman Make)
Rolling Shutters 21 Nos Of Motorized Rolling Shutters
Fire Fighting System NFPA Standard -Fire Water Pumping System Fire Hydrant System Fire Detection Alarm & Sprinklers System ESFR Fire Tank With Backup Fire Tanks.
Others

4. Lighting High Bay LED Lighting System
Flooring 7 MT Point Loading
STP 40 KLD Of STP Sintex Make
Roads & Drainage System CC Roads For 20 MT Axel Load And Surface Drainage With NP 2 Pipes
Landscaping Avenue Plantation With Drip Irrigation Along The Compound Wall
Compound Wall 6ft Height Compound Wall With 2 Ft Concertina Wire Fencing


5 .Ancillary Building Separate Ancillary Buildings For Toilet Canteen Drivers Rest Room Driver Toilets, Electrical And Pump Room

6. Security Completely Compounded Facility With Gate And Security Room.